Member Move/Stretch, Include Material ( Modeling )
Tool summary :
- Both Move/Stretch Include Material (this tool) and Member Move/Stretch behave in exactly the same way with respect to moving members. However, when you stretch a member (by grabbing a member end (
)), the two tools behave in different ways.
Move/Stretch Include Material | Move/Stretch | |
Graphical connection material, bolts, welds |
Graphical connections move when the member end ( ![]() |
Graphical connections do not move when a member end is stretched. See example 1 . |
User-created materials | User-added materials move when the member's left end is stretched. See example 3 . They do not move when the member's right end is stretched. | User-added materials do not move when a member's left end (or right end) is stretched. See example 3 . |
Custom components |
Both tools produce the same result. That "same result" depends on the type of component, the component's settings and, for some components, which end ( ![]() |
|
System connections | Both tools give the same result. The connection material associated with the end that is stretched moves with the end that is stretched. See example 2 . | |
Member main material |
Main material stretches when either end ( ![]() |
Main material stretches when either end ( ![]() |
page 1 | contents | model > member > | model -- member | member tools | top
Example 1: Stretching a member with graphical connection material:
![]() |
These three columns were exact copies of one another before the middle and right columns were stretched. The user cap plate on all three columns is " ![]() ![]() |
![]() |
Here's a similar example with beams. The clip angle on all three members is " ![]() ![]() |
page 1 | contents | model > member > | model -- member | member tools | top
Example 2: Stretching a member's right end (
), effect on system-created connection material and user-created material:
![]() |
These two columns were exact copies of one another before the top end of the column on the right was stretched. The stiffener was not moved because it is user-created material . Both Move/Stretch and Move/Stretch Include Material would produce exactly the same results since it is the right end (top end) of the column that is stretched. If the left end of the member had been stretched, Move/Stretch Include Material would have moved the stiffener. |
![]() |
Here's an example of two beams, both with a system-generated clip angle connection. Neither connection is graphical. After the bottom beam was stretched using either Move Stretch or Move/Stretch Include Material , the system connection was regenerated as shown. The position of the user-created stiffener at the middle of the beam is not affected by the stretch operation since it is the right end of the member that is stretched. Compare this with example 3 , in which the left end of the member is stretched. |
page 1 | contents | model > member > | model -- member | member tools | top
Example 3 : Stretching a member's left end (a vertical column's bottom end), effect on user-created material:
![]() |
These three perfectly vertical columns were exact copies of each other before the bottom ends of the middle and right columns were stretched. The three column plates are user base/cap plates. The stiffener under each of these cap plates is user-created material . That stiffener is not moved in the middle example because Move/Stretch was used to perform the operation. |
Note: The left end of a perfectly vertical column is its bottom end. User-created material is placed along a member at specific distances from that member's left end. |
![]() |
These three beams were exact copies of each other before the left ends of the middle and bottom beams were stretched. The three right-end system connections are welded clip angles with web extension plates. It makes no difference in this example whether the connections are graphical or not since they are right-end connections and it is the left end that is stretched. The stiffener near the center of each of these beams is user-created material . That stiffener is not moved in the middle example because Move/Stretch was used to perform the left-end stretch operation. |
page 1 | contents | model > member > | model -- member | member tools | top
Example 4 : Stretching a beam's end (
), effect on custom components:
![]() |
These two beams were exact copies of one another before the right end of the bottom beam was stretched. The custom component Beam Stiffeners - Beam was used to generate the stiffeners. Either Move Stretch or Move Stretch Include Material could be used to produce the result shown in this example. The " Location method " of ' Fixed Spacing ' specifies that stiffener spacing be based on the overall length of the beam. |
![]() |
These two beams were exact copies of one another before the right end of the bottom beam was stretched. The custom component Beam Stiffeners - Beam was used to generate the stiffeners. Either Move/ Stretch or Move/Stretch Include Material could have been used to perform the stretch operation shown in this example. " ![]() |
Note: Since custom components are created by different developers for different purposes, you will find that different custom components behave in different ways when their members are stretched. However, it should make no difference whether the custom component's member is stretched using Move/ Stretch or Move/Stretch Include Material .
page 1 | contents | model > member > | model -- member | member tools | top